BV CPS Header
BV CPS More Products
RoHS / Analytical Testing
ATEX
Electrical Safety
EMC
Environmental
IT Interoperability
NEBS
Radio, Telecoms & IT
   - WiMAX
   - WiFi / WLAN


Testing

Electromagnetic Compatibility (EMC) Testing

LCIE, a Bureau Veritas Electrical company, EMC chamberBureau Veritas Electrical has decades of collective expertise in electromagnetic compatibility (EMC) testing and problem solving. Our highly trained staff have helped hundreds of client companies overcome the obstacles presented by Electromagnetic Compatibility / EMC challenges.





Our facilities are extremely modern. They include:

  • in excess of 15open area test sites located adjacent to our full service laboratories
  • over 20 anechoic chambers
  • many harmonics & flicker, surge and ESD rooms
  • and much more besides
Curtis Straus, a Bureau Veritas company, Open Area Test Site EMC facility

From CE marking to NEBS to transmitters to in-situ testing, we know Electromagnetic Compatibility / EMC.

Keeping Abreast of Regulatory Developments: As well as delivering a comprehensive range of Electromagentic Compatibility (EMC) testing for consumer, industrial and defence/aerosapce markets we also test to the many draft standards that are evolving in the world today. We constantly monitor the latest standard releases and updates to assure that Bureau Veritas remains on the cutting edge as an industry leader in the field of EMC / Electromagnetic Compatibility regulatory compliance. In fact, many of our senior engineers are members of some of the technical committees that write these standards. Our participation assures you that we are up to date on the regulatory issues facing you now and in the future.

Problem Solving: Bureau Veritas is widely known for bringing its considerable expertise to focus on EMC problems. If your product fails to meet one or more of the EMC criteria initially, we can help you diagnose and fix your product in as cost effective and expeditious a manner as possible. We offer design consulting at all stages of product design. We can also provide in-house seminars to train your engineers in designing for EMC success.

Electromagentic Compatibility (EMC) Test Laboratory Locations

Electromagentic Compatibility (EMC) Experts also in:

Bureau Veritas tests a wide variety of National and International standards for EMC. These include but are not limited to:

  • BETS-7 - Technical Standards and Requirements Radio Apparatus Capable of Receiving Television Broadcasting
  • CISPR 11 / EN 55011 /CNS13803 / FCC 47 CFR Part 18 - Industrial, medical, and scientific product EMI test
  • CISPR 13 / EN 55013 / CNS 13439 / J55013 / GB 13837 / K55013 / AS/NZS CISPR 13 - Sound, television and broadcast receiver EMI test
  • CISPR 14-1 / EN 55014-1/ CNS13783-1 - Household electronic product EMI test
  • CISPR 14-2 /EN 55014-2 - Household electronic product immunity test
  • CISPR 15 / EN 55015 / CNS14115 / FCC 47 CFR Part 18 - Lighting product EMI test
  • CISPR 20 / EN 55020 / CNS 14409 / K55020 - Sound, television and broadcast receiver immunity test
  • CISPR 22 / EN 55022 / CNS 13438 / VCCI V-3 / FCC 47 CFR Part 15B - Information Technology Equipment EMI test
  • CISPR 24 / EN 55024 - Information Technology Equipment immunity test
  • D-Book - CE Mark voluntary requirement
  • EN 300 386 - Telecommunication Network Equipment EMC test
  • EN 50081-1 /EN 61000-6-3 - Generic emission standard for residential, commercial and light-industrial environments
  • EN 50081-2 /EN 61000-6-4 - Generic emission standard for industrial environments
  • EN 50082-1 /EN 61000-6-1 - Generic residential, commercial and light-industrial environment immunity test
  • EN 50082-2 /EN 61000-6-2 - Generic industrial environment immunity test
  • EN 50091-2 - Uninterruptable Power Systems (UPS) Part 2: EMC requirements
  • EN 50130-4 - Alarm system immunity test
  • EN 60555-2 IEC/ EN 61000-3-2 / GB 17625.1 - Harmonic current emissions test
  • EN 60555-3 IEC/ EN 61000-3-3 - Voltage fluctuation and flicker test
  • EN 61204-3 - Low Voltage Power Supplies, DC Output Equipment EMC test
  • EN 61547 - General lighting purpose immunity test
  • EN50082-1, EN50082-2, EN55024, EN60601-1-2 and EN61800-3 for immunity requirements.
  • EN55022, EN55011, EN55013, EN55015 and EN50091-2 for radiated and conducted emissions.
  • ENV 50204 - 900MHz radio frequency pulse immunity test
  • ETSI 300 386-1, ETSI 300 132-2 for European Telecommunications Standards.
  • FCC Part 15, 22, 18 and 90 for intentional and unintentional radiators.
  • IEC / EN 60601-1-2 - Medical Electrical Equipment EMC test
  • IEC / EN 61000-4-11 - Voltage dips and interruptions immunity test
  • IEC / EN 61000-4-12 - Ring wave immunity test
  • IEC / EN 61000-4-2 - ESD immunity test
  • IEC / EN 61000-4-3 - Radiated, radio-frequency, electromagnetic field immunity test
  • IEC / EN 61000-4-4 / CNS 14676-4 - Electrical fast transient/burst immunity test
  • IEC / EN 61000-4-5 / CNS 14676-5 - Surge immunity test
  • IEC / EN 61000-4-6 - Conducted disturbance susceptibility test
  • IEC / EN 61000-4-8 - Power frequency magnetic field immunity test
  • IEC / EN 61326 - Electrical Equipment for Measurement, Control and Laboratory Use Equipment EMC test
  • MPR II, TCO - Low frequency radiation test
  • RTCA & MIL STAN specifications and standards for military and aerospace markets